Reference Levels for Occupational and Public Exposures to Electric and Magnetic Fields - ICNIRP* (2010) Guidelines

Reference Level - Magnetic Flux Density

Exposure Characteristics Miscrotesla (µT) Milligauss (mG)
Occupational 1000 10000
General Public 200 2000

Source: Ministry of Health. 2013. Electric and Magnetic Fields and Your Health. Wellington: Ministry of Health. *The International Commission on Non-Ionizing Radiation Protection (ICNIRP) is an international body and is recognised by the World Health Organisation (WHO) for its expertise in the area of Electric and Magnetic Fields.

Measurements on Powerlines

Network Measurement at Device Measurement 1m Away
Zone Subs (Fence) 1.5 µT -
Under 66kV Line 0.5 µT (1.5 above ground) -
Under 33kV Line 0.5 µT (1.5 above ground) -
Under 11kV Line 0.5 µT (1.5 above ground) -
Under 11kV & 400V Line 0.5 µT (1.5 above ground) -
11kV/400V Overhead Sub (Transformer) 1.5 µT -
11kV/400V Padmount 30 µT 3 µT
Andelect 1.5 µT 0.5 µT
Service Box 8 µT 1 µT

Measurements at Home

Domestic Measurement at Device Measurement 1m Away
Portable Radio 1 µT 40 nT
Portable Fan > 100 µT 2 µT
Hairdryer 40 µT -
Electric Shaver > 100 µT -
Rechargeable Shaver 0.5 µT -
TV (CRT) 4 µT 200 nT
Computer Screen 2 µT 40 nT
Plug Adaptor > 100 µT 80 nT
Extractor Fan 3 µT 80 nT
Electric Blanket 2 µT -
Computer Screen (LCD) 1.5 µT 300 nT
Electromagnetic Cooktop 8 µT 40 nT
Clock Radio 80 µT 40 nT
Meter Box 6 µT 60 nT